Apart
from manufacturing the mentioned test sets, we also
manufacture equipment according to
specific requirements of
customer.
pRnt02
rnt5 & rnt5a
RNT33 & znt33
RNT3
scnt2a
GPRNT2
GPRNT4
variable frequency source
to test frequency relay
Time
interval meter (1 & 3 channel)
phase
shifting transformer
This is a portable Relay Testing Kit in two
units suitable to test different types of relays like
over current,
overvoltage, undervoltage, earthfault etc. This
set is suitable to be used both in laboratory as well as at
site.
Input:
230 volts,
single phase, and 50Hz. AC.
Output(s):
a)
Current output(s)
available one at a time by smooth variation of variable autotransformer.
Range: 0-1,5,10,25 & 50A.
Capacity: 500VA Max.
Multi-ratio wound primary measuring CT with
digital metering.
Protection
against overload, short circuit provided.
b)
Voltage Output(s):
1) Continuously
variable 0 to 250V AC at 2A Max. with digital metering.
2)
Fixed
30V,
63.5V &
110V DC voltage of 50VA capacity,
selectable one at a time.
Output a) or b) available at a time.
c)
Time Interval Meter
Measuring
Range :
9.999secs.
& 99.99secs.
-----------Back
to Top-----------
RNT5
& RNT5A are portable Relay Testing Kit in one unit
suitable to test different types of relays like over current,
overvoltage, undervoltage, earthfault etc.

RNT5A
Relay Test
Set (Type: RNT-5A) |
Input:
230
volts, single phase, 50Hz. AC.
Output(s):
a) Current output(s)
available one at a time by smooth variation of variable autotransformer.
Type
Current Range
Capacity
RNT5
0-1,2,5,10,20,50,100
& 200A AC
600VA Max.
RNT5A
0-5,10,25,50,100
& 200A AC
1200VA Max.
Multi-ratio
wound primary measuring CT with analog metering.
Protection
against overload, short circuit provided.
b)
Voltage Output(s):
Continuously variable 0 to 250volts AC at 2A Max. with
analog metering.
Fixed 50V
&
110V AC at 2 A, selectable one at a time.
For RNT5 either a)
or b) output is available.
For RNT5A, fixed voltage output facility is not
provided.
c)
Time Interval Meter
Measuring Range:
9.999secs. &
99.99secs.
-----------Back
to Top-----------
"NTPL" make Relay Test Set, RNT33
& ZNT33 are suitable for testing distance relays. However,
other relays
like overcurrent, over voltage, undervoltage,
earthfault etc. can also be tested by this relay test
set.

ZNT33 |
Input Voltage:
415V+10%, 3 phase, 4 wire, 50Hz. AC.
Output(s):
[a]
Current output(s) [3 phase] available by
smooth
variation of variable autotransformer.
Range: 0 to 1,5,10,25 &
50A having 0 to 100% regulation in each tap selectable one
at a time.
Rated maximum
burden: 250VA.
Protection
against overload, short circuit provided.
Multi-ratio
wound primary measuring CT.
[b]
Voltage Output(s):
RNT33:
110V, 3 phase 50Hz. AC having
6 different taps at 10%, 70%, 80%, 90%, 100% & 110%.
Rated maximum
burden: 250VA.
Only B phase is continuously
variable at any of the selected tap voltage.
DC voltage source: Isolated 0-110V/220V
continuously variable DC of 100VA, without metering will be
available
for 30 mins.
ZNT33:
110V AC, phase to phase,
63.5V phase to neutral, 3 phase 50Hz. AC continuously variable
from 0 to
110%. Rated maximum burden: 250VA.
DC voltage source:
Isolated
30V/110V/220V continuously variable DC of 100 VA, without
metering will
be available for 30 mins.
[c] Phase Shifter
Phase Shifting can be done at any value between 0 to 3600
by coarse & fine control. Capacity: 250VA.
[d]
Time Interval Meter
Measuring Range: 9.999secs.
& 99.99secs.
Special
feature:
ZNT33: Added
facility over RNT33 is in selection of fault vector in 1 phase
to earth fault or phase to
phase fault. In ZNT33, the voltage
of the healthy phase will remain unaltered.
Current, Voltage, Phase angle variation,
Timer measurement will be indicated by respective digital meters.
-----------Back
to Top-----------
RNT3
“NTPL” make RNT3 is a portable Relay Test
Set in one unit suitable to test distance relays. It can also
be
used for testing power directional relays, voltage relays,
current relays etc.
Input:
400 V or 110V, 50Hz., 3 phase, 4 wire
AC
Output(s)
[a]
Current Output (any one of the 3 phases, selectable at
a time) available by
smooth
variation of
variable autotransformer.
Range: - 0 to
1,5,10 & 50A having 0-100% regulation. Capacity: 200VA
Max.
Protection
against overload, short circuit provided.
[b]
Voltage Output (any one of the 3 phases, selectable at
a time):
110V (ph. to ph.)
Or
63.5 V (ph. to n).
Capacity: 200VA
Max.
[c]
Phase Shifter
Phase Shifting can be done at any value between 0 to
3600 by coarse & fine control.
Capacity: 200VA Max.
Current, Voltage & Phase Angle Variation will be indicated
by respective digital meters.
-----------Back
to Top-----------
SCNT2A
This
is a portable Secondary Current Injection Kit in one unit,
suitable to test protective device like relays,
circuit
breakers and similar equipment. The Set is designed for both laboratory and field use.

SCNT2A |
Input: 230volts,
single phase, 50Hz. AC.
Output(s):
a)
Current output
(One
output at a time.) continuously variable by smooth variation
of variable
autotransformer .
Range:
0 to 1,5,10,20,30 & 60A having 0-100% regulation.
Capacity:
500VA Max.
Multi-ratio wound primary measuring CT with analog metering.
Protection
against overload, short circuit provided.
b) Voltage Output:
Continuously variable 0 to 250 V AC or DC with analog
metering.
Capacity:
2A Max.
c) Time Interval meter Measuring Range: 9.999secs.
Or 99.99secs.
-----------Back
to Top-----------
GPRNT2
This is a portable Testing Kit in one unit, suitable to test
different types of relays like overcurrent, under or over
voltage, overload, various AC & DC auxiliary relays.
Input: 230volts,
single phase, 50Hz. AC.
Output(s):
a)
Current output
(One
output at a time)
continuously
variable by smooth variation of variable
autotransformer .
Range: 0 to 5, 20 & 60A having 0-100% regulation.
Capacity:
300VA Max.
Multi-ratio wound primary measuring CT with analog metering.
Protection against overload, short circuit provided.
b) Voltage Output(s):
AC Voltage Output:
Continuously variable 0 to 150V AC at 1 A
or 0 to 300V AC at 0.5A.
Fixed DC Voltage Output:
30V,
110V, 220V DC selectable one at a time. Capacity: 50VA.
Analog metering provided.
c) Time
Interval meter
Measuring Range: 9.999secs.
&
99.99secs.
d)
Facility for continuity
test provided. Polarity test of CT & PT also provided.
-----------Back
to Top-----------
GPRNT4
This is a portable Relay Testing Kit in one unit, suitable to
test different types of relays like overcurrent,
overvoltage,
undervoltage, overload, various AC & DC auxiliary relays etc.
Input:
240volts,
single phase, 50Hz. AC.
Output(s):
a)
Current
Output (One output at a time) continuously
variable by smooth variation of variable
autotransformer.
Range: 0 to 2, 20 & 100A having 0-100% regulation.
Capacity:
1KVA Max.
Multi-ratio wound primary measuring CT.
Protection against overload, short circuit provided.
b) Voltage Output:
Continuously variable 0 to 250V AC at 0.75A.
Continuously variable 0 to 300V DC at 0. 5A.
c)
Time
Interval meter
Measuring Range:
9.999secs.
Or
99.99secs.
Respective
digital meters will indicate current & voltage
measurement.
-----------Back
to Top-----------
VARIABLE FREQUENCY SOURCE
TO TEST FREQUENCY RELAY
This Test Kit is suitable for testing of
frequency-operated relays having burden upto 20 VA Max. Sine
waves and frequency ranging from 45 to 55 Hz. are generated
& digital meters indicate the measured
frequency as well
as the voltage.
Input
Power Supply :
240 V ± 10%, 50 Hz., single phase, AC.
Output Voltage
:
Continuously variable 0-240 V.
Range
:
45 to 55Hz.
Burden
:
20
VA max.
Distortion
: Less than 5%
Protection against overload, short circuits, voltage spikes are provided.
The Set has high immunity against
external electric and
electromagnetic fields noise etc.
-----------Back
to Top-----------
Time
Interval Meter (1 & 3 channel)
"ntpl" Digital Time Interval Meter is suitable for measuring, "switching"
time of relays, "trip"(actuation
time) time and "ON" (recovery time) time of circuit breaker, fusing time
of fuse elements, travel time of switches.
Type: NTT4D
Input Power Supply
|
:
230 volts, AC + 10% at 50 Hz.
|
|
Display |
:
Four-digit display with 7 segments LED
|
|
Range
|
:
9.999secs. OR 99.99 secs |
|
Accuracy |
:
+ 1
% |
Type: NTT3ch4D
The above time interval counter is particularly suitable to check
simultaneous operation in three
different
channels.
Range
:
999.9msecs. Or
9.999secs.
All the other technical features will be same as Type
NTT4D