Apart
from manufacturing the mentioned test sets, we also
manufacture equipment according to
specific requirements of
customer.
OIL
TEST SET
TRANSFORMER TURNS RATIO METER
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
AC
HIGH VOLTAGE TEST SET
TRANSFORMER WINDING RESISTANCE METER
TAN
DELTA RESISTIVITY TEST FOR INSULATING OIL
CAPACITANCE
& TAN-DELTA TEST SET FOR HIGH VOLTAGE EQUIPMENT
PARTIAL
DISCHARGE TEST SET
MICRO OHM-METER
NO
LOAD & LOAD TEST BENCH
INSULATION
RESISTANCE CUM POLARISATION INDEX TEST KIT
IMPULSE
VOLTAGE GENERATOR
OIL TEST SET
“NTPL” make Oil Test Set is ideal for testing of
Breakdown/withstand test of transformer and circuit breaker oil, in accordance with IS 6792:1992 for
oil testing.
Input:
230V + 10%, 50Hz., 1 phase AC.

Manually
Operated
Oil Test Set
(50 KV - 80 KV) |

Motor
Operated
Oil Test Set
( 50 KV - 80 KV) |

Microprocessor
based
Fully Automatic
Oil Test Set |

Manually
Operated
Oil Test Set
(90 KV-120 KV) |

Motor
Operated
Oil Test Set
(90 KV - 120 KV) |
Selection
chart:
|
Mode
of operation
|
Type
|
Maximum
output(In kV)
with
center point of H.V.winding grounded
|
|
Manually
operated
|
OTMN050S
OTMN060S
OTMN070S
OTMN075S
OTMN080S
OTMN090S
OTMN100S
OTMN120S
|
50
60
70
75
80
90
100
120
|
|
Motor
operated
|
OTMT050S
OTMT060S
OTMT070S
OTMT075S
OTMT080S
OTMT090S
OTMT100S
OTMT120S
|
50
60
70
75
80
90
100
120 |
|
Microcontroller/Microprocessor
based Fully Automatic
|
OTAU050S
OTAU060S
OTAU070S
OTAU075S
OTAU080S
OTAU090S
OTAU100S
OTAU120S
|
50
60
70
75
80
90
100
120
|
Capacity:
10mA in the HT side for all sets.
Transformer: H.V. Transformer used in the Test set is cast resin
type of graded insulation with center
point of H.V. winding grounded.
Protection: Zero start
interlocking & door-interlock is to be provided. Snap
acting automatic tripping of
H.V. circuit in case of overload or
breakdown of oil sample under test.
Overvoltage
indication (audio & visual) is also incorporated.
Metering: Analog meter for manually & motor operated sets.
Digital display for automatic
sets.
Test Vessel: As per IS 6792:1992. A gauge is provided along with the
cell to adjust the gap.
Features that can be provided at extra cost for manually & motor
operated sets:
Capacity
other than standard setting, Digital Metering, Stirring
arrangement, Mushroom electrode,
Cylindrical electrode.
-----------Back
to Top-----------
TRANSFORMER TURNS RATIO METER
Transformer Turns Ratio Meter is compact in size and is capable to
measure actual turns ratio of different types of transformers like Distribution,
Power, CT, PT, Auto-transformers, Control & Measuring transformers etc.
|

TTR10 |
|
FEATURES:
Suitable
to measure
percentage ratio error directly.
Polarity
indication by phase sensitive null detector.
Additional
3 phase switch network for Type TTR1P3, TTR10P3 & TTR20P3.
Direct
ratio error measurement range + 1% of the range with
resolution of 0.05 %.
Direct
ratio error measurement accuracy + 0.25% of the reading.
Null
indicator: Center zero
microampere meter fed through electronic null detector.
Digital meter may be provided at
extra cost.
Over
load / Short circuit & HT/ LT reversal protection.
Power
supply input: 230 volts ± 10%, single phase, 50 Hz. AC.
|
Type
|
Range
|
Accuracy of ranges
|
Least count on vernier
pot.
|
Excitation voltage
|
|
TTR1/
TTR1P3
|
1
to 111
|
+
0.1 for
1-50
+
0.15 for 50-111
|
0.0001
|
1/10/40
Volts AC
|
|
TTR10/
TTR10P3
|
1
to 1111
|
+
0.1 for 1-111
+
0.15 for
111-500
+
0.2 for 500-1111
|
0.0001
|
1/10/110
Volts AC
|
|
TTR20/
TTR20P3
|
2
to 2222
|
+
0.1 for 2-222
+
0.2 for 222-2222
|
0.0002
|
1.2/12/120
Volts AC
|
Note:
Type TTR1P3, TTR10P3 & TTR20P3 have 3-phase switching network
facility to make
interconnection cable operation easy.
-----------Back
to Top-----------
DOUBLE
FREQUENCY DOUBLE VOLTAGE TEST SET
This test set provides a continuously variable output voltage at
double frequency to test the insulation between turns of coils, layer to layer,
terminals of windings with either uniform or graded insulation
and
also between the windings
and earth, with graded insulation of both Distribution and
Power transformers.
An
alternating voltage of sine wave form (as much as possible) at double frequency (100 Hz.) and
double
in amplitude can be applied at one side of the transformer under test while
the
windings, which are not
connected to the source of excitation, are left
on open
circuit. This higher frequency is considered to
avoid excessive excitation current during the
testing.
|

dfdv020h
|
|
Voltage
source:
To generate a voltage at 100 Hz., one 3-phase squirrel
cage induction motor is given a supply through a star-delta switch. This motor drives the
slip ring induction motor (generator). A variable voltage is also supplied to the
generator thereby producing double frequency, which along with the output voltage of the
generator is available across the terminals of the Set.
Selection chart:
|
Type
|
Output
capacity of generator(slip-ring motor)
In
HP
in kW
|
Suitable
to test transformer upto
|
|
dfdv010h
|
10HP
7.5KW
|
250KVA
|
|
dfdv020h
|
20HP
15 KW
|
750KVA
|
|
dfdv025h
|
25HP
18.75KW
|
1MVA
|
|
dfdv030h
|
30HP
22.5KW
|
2MVA
|
|
dfdv040h
|
40HP
30KW
|
3MVA
|
|
dfdv050h
|
50HP
37.5KW
|
4MVA
|
|
dfdv060h
|
60HP
45KW
|
5MVA
|
|
dfdv080h
|
80HP
60KW
|
6MVA
|
|
dfdv100H
|
100HP 75KW
|
7.5MVA
|
|
dfdv150h
|
150HP
112.5KW
|
11.2MVA
|
Protection
against over load, short circuit & single phasing provided.
Metering:
Digital frequency meter, ammeters & voltmeters. Ammeter and
voltmeters are connected to CT &
PT of proper current and voltage ratio.
Duty
cycle -
Suitable for 1 minute withstand test of transformer.
Optional at extra cost:
Step up transformer for testing 33/11 kV Power
Transformers provided.
-----------Back
to Top-----------
AC
HIGH VOLTAGE TEST SET
NTPL"
make
High voltage testing sets are suitable for Power frequency AC high
voltage test on transformers, motors, insulators, cables etc. The
sets are capable of giving continuously variable AC HIGH VOLTAGE
from zero to maximum rated output voltage.

High
Voltage Test Set
(Oil Cooled) |

High Voltage
Test Set
(Dry Type) |
Input:
Generally,
230 Volts, 50Hz, single phase AC, upto 10KVA & 400/415V,
two phase out of three
phases for sets beyond 10KVA.
However,
we also manufacture AC H.V. sets workable on other input voltage at
extra cost.
Output:
Continuously variable from zero to maximum rated output voltage.
Capacity:
Spread over a wide range of sets from 2.5KV to 300KV AC having
capacities from several VA to hundreds of
KVA.
Duty
cycle:
Intermittent i.e., 5
minutes ON, 10 minutes OFF. However, test sets of continuous or
other duty cycles can also be manufactured at extra cost.
Metering:
Analog voltmeter & milliammeter/ammeter. Digital meters may be
provided at extra cost.
Protection:
Tripping mechanism for protecting the H.V. transformer
against over loading. The tripping mechanism can be adjusted at
25,50 & 100% of the rated current by a rotary switch. Below
100mA &
above 20mA two adjustable tripping ranges are at 50%
&100%, while for sets of 20mA capacity or below only 100% is
adjustable [If required by the users tripping current can be made
adjustable at other values, at extra cost].
Apart
from tripping mechanism, Zero start interlocking along with
Overvoltage alarm & indication are provided.
Mode
of operation: Sets are generally, motor operated beyond 20KVA & 50KV. Motorisation facility can be available below the specified value at
extra cost.
H.V
Transformer:
H.V.Transformer
used for the testing purpose can be oil cooled indoor type or Resin
cast dry type as found suitable or particularly required by the
customer. The H.V. winding of the high voltage testing transformers
is of graded insulation, one end of which is grounded through
milliammeter and tripping device while the other end remains in
floating condition as H.V. terminal. These testing transformers are
specially designed to withstand frequent intermittent spark over or
momentary short circuit conditions under which such testing
transformers are supposed to operate.
Discharge
Rod:
For
device under tests having large capacitance, discharge rod may be provided at an extra cost.
While
sending enquiry for quotation or order please specify the following:
Input
voltage and frequency.
Maximum
output voltage.
Capacity.
Type
of transformer –Oil cooled or Cast Resin
Duty
Cycle.
Mode
of operation: Manual/Motor operated.
Any
other details you find important to be specified.
-----------Back
to Top-----------
TRANSFORMER
WINDING RESISTANCE METER
This Test set is suitable to measure
winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent
displays read the resistance of both primary & secondary windings simultaneously.
However, primary or secondary winding can also be measured separately.
DC Power source allows the
selected current to flow through the winding /windings and the voltage developed
across the winding are sent to instrumentation amplifiers, thereby displaying directly the
ohmic value.
|

UONT010A |
|
Technical Features:
| Resistance
Range
|
Resistance
meter reading display
|
Resolution
|
Test
Current
|
Type
UONT005A |
Type
UONT010A |
| 2mW |
19.99x0.1 |
1mW |
5A |
10A |
| 20mW |
19.99x1 |
10mW |
5A |
10A |
| 20mW |
199.9x0.1 |
10mW |
500mA |
1A |
| 200mW |
199.9x1 |
100mW |
500mA |
1A |
| 0.200W |
1999x0.1 |
100mW |
50mA |
100mA |
| 2W |
1999x1 |
1mW |
50mA |
100mA |
| 2W |
19.99x0.1 |
1mW |
5mA |
10mA |
| 20W |
19.99x1 |
10mW |
5mA |
10mA |
| 20W |
199.9x0.1 |
10mW |
0.5mA |
1mA |
| 200W |
199.9x1 |
100mW |
0.5mA |
1mA |
| 200W |
1999x0.1 |
100mW |
0.05mA |
0.1mA |
| 2KW |
1999x1 |
1W |
0.05mA |
0.1mA |
Input Power
Supply: 230V +10%, single phase, 50Hz. AC.
Accuracy:
+1% of selected resistance range.
Display:
2 nos., 31/2 digit LED module for resistance measurement.
Protection:
Protection
against current lead disconnection while in use, Induction
Kickback suppression, Snap acting
overload protection.
-----------Back
to Top-----------
TAN-DELTA
& RESISTIVITY TEST FOR INSULATING OIL
Type:
tdrnt02
TDRNT02 measures dielectric parameters like D.C.
resistivity,
dielectric constant and loss factor of the
insulating oil of transformers, circuit
breakers etc.
Loss
angle & dielectric constant MODE:
This
mode can measure dielectric constant & dissipation factor (tanδ).
Measuring Range
: Dielectric constant 1 to
10
Dissipation factor 0.01% to 100%
Accuracy
: Dielectric Constant + 2% of reading + .001 of
FSD
Dissipation factor + 3% of reading + .0001 tanδ
Test Voltage for loss factor
: 0 to 2000 V AC, 50 Hz.
Metering
: Digital
Resistivity
mode:
This
mode is provided with 500 V DC power supply with accuracy of +
5% to measure the
resistivity of the sample under test.
Range
: 109 to 1016 ohm-cm in 7 ranges.
Test
Voltage
: 500 V DC.
Accuracy
: +
10% of reading + 2% of corresponding range FSD
Metering
: Analog
Three
Terminal oil CELL:
The
cell is fabricated out of stainless steel and Teflon is the
insulating material used for isolation of the
three electrodes i.e. H.T. Electrode, Guard
Electrode and Central Electrode.
Heating
CHAMBER:
This
chamber uniformly heats the test cell and sample under test upto
desired temperature to a maximum
limit of 1200
C.
Temp.
Range
: From |