                                                              AC HIGH VOLTAGE BREAKDOWN TEST SET     
 
HOME  |  PROFILE  | PRODUCT  |  CLIENTS  |  CONTACT  |  FEEDBACK

     Apart from manufacturing the mentioned test sets, we also manufacture equipment according to 
  specific requirements of customer. 
  

                                               AC HIGH VOLTAGE TEST SET 

NTPL" make High voltage testing sets are suitable for Power frequency AC high voltage test on transformers, motors, insulators, cables etc. The sets are capable of giving continuously variable AC HIGH VOLTAGE from zero to maximum rated output voltage.  


 High Voltage Test Set
(Oil Cooled)

High Voltage Test Set
(Dry Type)

Input: Generally, 230 Volts, 50Hz, single phase AC, upto 10KVA & 400/415V, two phase out of three 
phases for sets beyond 10KVA.
However, we also manufacture AC H.V. sets workable on other input voltage at extra cost.

Output:
Continuously variable from zero to maximum rated output voltage.

Capacity:
Spread over a wide range of sets from 2.5KV to 300KV AC having capacities from several VA to hundreds of  KVA.
Duty cycle:
Intermittent i.e., 5 minutes ON, 10 minutes OFF. However, test sets of  continuous or other duty cycles can also be manufactured at extra cost.  

Metering:
Analog voltmeter & milliammeter/ammeter. Digital meters may be provided at extra cost.

Protection:
  Tripping mechanism for protecting the H.V. transformer against over loading. The tripping mechanism can be adjusted at 25,50 & 100% of the rated current by a rotary switch. Below 100mA & 
above 20mA two adjustable tripping ranges are at 50% &100%, while for sets of 20mA capacity or below only 100% is adjustable [If required by the users tripping current can be made adjustable at other values, at extra cost].  
Apart from tripping mechanism, Zero start interlocking along with Overvoltage alarm & indication are provided.

Mode of operation:
Sets are generally, motor operated beyond 20KVA & 50KV. Motorisation facility can be available below the specified value at extra cost.

H.V Transformer:  
H.V.Transformer used for the testing purpose can be oil cooled indoor type or Resin cast dry type as found suitable or particularly required by the customer. The H.V. winding of the high voltage testing transformers is of graded insulation, one end of which is grounded through milliammeter and tripping device while the other end remains in floating condition as H.V. terminal. These testing transformers are specially designed to withstand frequent intermittent spark over or momentary short circuit conditions under which such testing 
transformers are supposed to operate.

Discharge Rod:
For device under tests having large capacitance, discharge rod may be provided at an extra cost.

While sending enquiry for quotation or order please specify the following:
 
        Input voltage and frequency.
         Maximum output voltage.
         Capacity.
        Type of transformer –Oil cooled or Cast Resin
         Duty Cycle.
         Mode of operation: Manual/Motor operated.
         Any other details you find important to be specified.  

                                         -----------Back to Top-----------      

                                                  DC HIGH VOLTAGE TEST SET 


DC High Voltage Test Set
( Cascaded  Type)
)



DC High Voltage Test Set
( In Two Units)

NTPL" make High voltage testing sets are suitable for testing electrical insulation of condensers,  transformers, motors, insulators, cables etc. The sets are capable of giving continuously variable DC HIGH VOLTAGE from zero to maximum rated output voltage.

Input: Generally, 230 Volts, 50Hz, single phase AC. 
However, we also manufacture DC H.V. sets workable on other input voltage at extra cost.

Output: Continuously variable from zero to maximum rated output voltage.

Capacity: Spread over a wide range of sets from 1 KV to 300KV with current capacity upto 100mA.

Sets of higher current capacity can also be manufactured.
 

Duty cycle: Intermittent i.e., 5 minutes ON, 10 minutes OFF. 

However, test sets of continuous or other duty cycles can also be manufactured at extra cost.

Metering: Output DC high voltage measured by HV resistor chain along with micro-ammeter scaled in kV.
Milli-ammeter to measure the leakage current.
Digital meters may be provided at extra cost. 

Protection: Overload & short circuit provided. Zero start interlocking along with Overvoltage alarm & indication are provided. 

Mode of operation: Generally, sets are manually operated. Motorisation facility can be available at extra cost.

Units: Generally DC high voltage test sets are available in one unit upto 35KV and sets of higher output voltage are commonly manufactured in two units i.e. the control unit & Transformer–Rectifier unit. This Transformer–Rectifier unit are made cascaded type above 80KV. However, NTPL always welcome customers' choice regarding the no. of units.

Discharge rod: A discharge rod is provided with the set.

DC high voltage is generally obtained by simple rectification of AC high voltage or by multiplication of relatively low AC high voltage by proper multiplier circuits as is found suitable for a particular DC HV test set. HV transformers of the Test Sets are Cast Resin types.  

While sending enquiry for quotation or order please specify the following:
 
       Input voltage and frequency.
         Maximum output voltage.
 
       Capacity.
 
       Duty Cycle.
 
       Mode of operation: Manual/Motor operated.
 
       Any other details you find important to be specified. 

                                          -----------Back to Top-----------

                                                           OIL TEST SET 

“NTPL” make Oil Test Set is ideal for testing of Breakdown/withstand test of transformer and circuit breaker oil, in accordance with IS 6792:1992 for oil testing.

Input:
230V + 10%, 50Hz., 1 phase AC.


Manually Operated
Oil Test Set 
(50 KV - 80 KV)

Motor Operated
Oil Test Set
( 50 KV - 80 KV)

Microprocessor based
Fully  Automatic 
Oil Test Set

Manually Operated 
Oil Test Set 
(90 KV-120 KV)

Motor Operated 
 Oil Test Set 
(90 KV - 120 KV)
 

   Selection chart: 

Mode of operation

Type

Maximum output(In kV)  
with center point of H.V.winding grounded

Manually operated

OTMN050S
OTMN060S
OTMN070S
OTMN075S
OTMN080S
OTMN090S
OTMN100S
OTMN120S

             50
        60
        70
        75
        80
        90
       100
       120

Motor operated

OTMT050S
OTMT060S
OTMT070S
OTMT075S
OTMT080S
OTMT090S
OTMT100S
OTMT120S

       50
        60
        70
        75
        80
        90
       100
       120

Microcontroller/Microprocessor based Fully Automatic

OTAU050S
OTAU060S
OTAU070S
OTAU075S
OTAU080S
OTAU090S
OTAU100S
OTAU120S

        50
        60
        70
        75
        80
        90
       100
       120

 Capacity: 10mA in the HT side for all sets.

  Transformer: H.V. Transformer used in the Test set is cast resin type of graded insulation with center  
  point of H.V. winding grounded.

  Protection:  Zero start interlocking & door-interlock is to be provided. Snap acting automatic tripping of  
  H.V. circuit in case of overload or breakdown of oil sample under test.

  Overvoltage indication (audio & visual) is also incorporated.

  Metering: Analog meter for manually & motor operated sets. Digital display for automatic  sets.

  Test Vessel: As per IS 6792:1992. A gauge is provided along with the cell to adjust the gap.

  Features that can be provided at extra cost for manually & motor operated sets:
  Capacity
other than standard setting, Digital Metering, Stirring arrangement, Mushroom electrode,  
  Cylindrical electrode.

                                                                 -----------Back to Top-----------  

                                      AC High Voltage Breakdown Test Set 

“NTPL” make 3KV or 5KV AC High Voltage Test Set is ideal for testing of Breakdown/withstand test of electrical  & electronic components etc.


AC High Voltage Breakdown Test Set

Input                        :           230V +10%, 50Hz., 1 phase AC.  
Output                     :        
 (Type: BDVMN03S) continuously variable from 0 to 3KV and 
                                     (Type: BDVMN05S) continuously variable from 0 to 5KV.  

Capacity                    :         50mA maximum in the H.V. side.  

Tripping Current    :
         Tripping current can be adjusted at 25mA & 50mA.  
Duty                         :
         Intermittent i.e. 5 minutes “ON” & 5 minutes “OFF”.  

H.V. Transformer: H.V. Transformer used in the Test set will be cast resin type.  

Protection: Snap acting automatic tripping of H.V. circuit in case of overload of sample under test. Zero start interlocking will be provided.  

Metering :
Analog type voltmeter & milliammeter.  

Mode of operation:
Sets will be manually operated.

Features that can be provided at extra cost:
 

       Tripping set other than standard setting  
 
       Digital Metering 

                                                                              -----------Back to Top-----------


               
AC AND DC COMBINED HIGH VOLTAGE TEST SET



The above test set is suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.



AC & DC Combined Test Set


Input : 230 volts, 50 Hz., single phase, AC. However, sets with other input voltage & 
          frequency are also manufactured if mentioned by the customer.


Output(s) 
AC Mode : Continuously variable from 0 to maximum rated output voltage. Spread over a wide range from several VA to hundreds of KVA. 


Tripping current: 25%, 50% & 100% of the rated current capacity. 



DC Mode : Continuously variable from 0 to maximum rated output voltage.
               This DC HV output can be suitably used in two modes.
               They are: -
               1) Cable fault-burning mode. 
               2) Cable insulation testing mode.


Only one output mode will be available at a time by brief manual change over.


Duty cycle: Intermittent i.e., 5 minutes ON, 10 minutes OFF. However,test sets of continuous 
                or other duty cycles can also be manufactured at extra cost.


Series: ADHVXXYYU; XX denotes Manual operation of the set (MN) or Motor operation of the 
          set (MT).
          YY denotes type of transformer i.e. cast resin type (DR) or oil cooled type (OC).
          U denotes no. of units.
This Series will be repeated for both AC & DC mode as Series1 & Series 2


Type1: X1X1X1KY1Y1Y1 m; X1X1X1 denotes the maximum rated AC output voltage.
          Y1Y1Y1 denotes the current capacity in mA.
          X1X1X1KY1Y1Y1 A; Y1Y1Y1 denotes the current capacity in Amp.


Type2: X2X2X2KY2Y2Y2 m; X2X2X2 denotes the maximum rated DC output voltage.
          Y2Y2Y2 denotes the current capacity in mA.


Protection: Overload & short circuit provided. Zero start interlocking along with Overvoltage  
               alarm & indication are provided.

Metering 
AC mode: Voltmeter, Rectifier type milliammeter. 

DC mode: Micro-ammeter scaled and connected to the HV resistor chain for direct DC HV 
              measurement.
              DC milliammeter to measure DC leakage / burning current 


HV Transformer:
The Transformer will be indoor pattern cast resin trolley mounted type with one end of the HV winding earthen through low impedance circuit element.
 
Rectifier unit:
This unit consists of diode chain, filter capacitors and resistor chain. The whole DC circuit element will be coupled to the transformer & control by simple & short manual operation.


Discharge rod: A discharge rod is provided with the set.



                                          -----------Back to Top-----------



                                             PARTIAL DISCHARGE test set

                                                                               type: pdnt02

This Test Kit is used for non-destructive means of assessing the quality of high voltage transformers, motors, cables etc., which are used in generation & distribution of electric power.  

The basic system consists of-

 
Discharge measuring module
    Input                     :  230volts, 50Hz., single phase AC.
   
Measuring Range: 0 to 5,50,500,5000pC in different switchable ranges.
                              Discharge pulses can be detected and measurement can be done in analog scale 
                              as well  as in PC.

 
MATCHED MEASURING IMPEDANCE
   
In series with standard capacitor this forms a voltage divider and decouples the high  frequency signals to
  feed the discharge measuring module. The set is electro statically shielded.

 
Standard Capacitor: 100pf or 1000 pf.
  C.R.O. suitable for the above
 
Calibrating Pulsar

 
OPTIONAL AT EXTRA COST:
  40 kV AC high Voltage measuring system 

  Auxiliary Supply Voltage: 230 Volts, 50Hz, single phase, AC.
  Range: 0 - 40 kV AC
  Metering: 31/2 digital panel meter.

                                                -----------Back to Top-----------

           CAPACITANCE  & TAN-DELTA TEST SET FOR H.V EQUIPMENT 

  Capacitance & Tan-Delta Measuring Equipment along with its accessories is suitable for testing motors,   
 
Power Transformers, H.V. Bushings, Generators, Power Capacitors, cables etc. at power frequency. 
  Periodic
measurement of dissipation factor & capacitance on new solid insulators and those on long 
  service period
produces comparative result about the trend of deterioration of insulation resistance before 
  insulation 
breakdown occurs.  
 
Thus, the set is ideal to conduct routine diagnostic tests on solid insulating components, equipment   
 
required for High Voltage generation, Transmission and Distribution.

  The Set is in four units:
  
    i. Capacitance & Tan-Delta Measurement Bridge
    
ii. High Voltage AC Power Supply Control Unit
   
iii. High Voltage AC Power Supply Transformer Unit
   
iv. Standard Capacitor   

Capacitance & Tan-Delta Test Set

  Standard test modes
  1.   UST -            UNGROUNDED SPECIMEN TEST.
   
       Reduces the effect of stray capacitance to ground. Maximum accuracy is obtained in this mode.
 
2.   GST -            GROUNDED SPECIMEN TEST.
  
       Mostly used in outdoor installations, power systems when the object under test is permanently 
       grounded. Exp. Windings of Transformer to tank and core, Coils of Rotating machine, circuit breaker 
       assembly etc.

 
3.   GST-G – GROUNDED SPECIMEN TEST WITH GUARD.
        
Performed to measure stray capacitance and separate it from values obtained in GST test.
 

 Capacitance & Tan-Delta Measurement Bridge
 

    Type                        Test Voltage               Current Capacity                     

  CTDNTE12                  0-12KV                         200mA Max. 
  CTDNTE20            
        0-20KV                          2A Max.                                                       

  Input: 230Volts, single phase, 50Hz. AC. 

  Capacitance measurement:  
  Value of Standard                 Cx  x four                      Resolution                         Accuracy
  Capacitor (Cs) used          multiplier range

  -------------------------------------              ------------------------------               ---------------------                -------------------------------------------
      
  100 pF                                   1 pF to 0.11
mF                  0.1 pF                    + 0.2% of reading + .1 pF
      1000 pF (1 nF)                     10 pF to 1.1
mF                      1 pF                     + 0.2% of reading + 1 pF
      10000 pF (10 nF)                 100 pF to 11
mF                   10 pF                     + 0.2% of reading + 10 pF 

  Tan – Delta measurement:
     Tan-Delta        Tan-Delta                         Resolution                                   Accuracy
  
      Factor                   Range
        ----------------               --------------------------                             ----------------------                               -------------------------------------------
       
    0.1               1 x 10-4 to 0.11                   2 x 10-6                        + 2% of reading + 2 x10-5
 
        
1.0                1 x 10-3 to 1.11                    2 x 10-5                        + 1% of reading + 2 x10-4
       
10.0              1 x 10-2 to 11.1                    2 x 10-4                        + 1% of reading + 2 x10-3

       Special shielding arrangement has been designed for this kit to suppress external interference. These  
  enable accurate measurements even in electrically noisy environment particularly in switchyards.

  High Voltage AC Power Supply

  Input: 415Volts, two phase out of three phase, 50Hz. AC. 

  Series            Type            Test Voltage             Current Capacity               Duty Cycle

  ACHVCTD     12K200m         0-12KV                      200mA                        15 mins.
                      
                                                                 
100mA                      continuous  
 ACHVCTD      20K2A            0-20KV                           2A                        30 mins.

                           
                                              1.5A                          60mins.
                                                                           1A                       continuous
 
Metering:
        31/2 digital panel voltmeter & ammeter

 Standard Capacitor

 
Wide range of NTPL Standard capacitors are load loss stable capacitors designed for use with Capacitance
 & Tan -Delta Bridge.