                                                                       METER TEST BENCH
 
HOME  |  PROFILE  | PRODUCT  |  CLIENTS  |  CONTACT  |  FEEDBACK

     Apart from manufacturing the mentioned test sets, we also manufacture equipment according to 
  specific requirements of customer. 
  

   PHANTOM LOAD TEST SET

   KWH METER TEST BENCH - 1PH

    KWH METER TEST BENCH - 3 PH/1PH

   PHASE SHIFTER

                                                Phantom Load Test Set 

These portable test sets with selectable three phase test voltage, adjustable test current and fully controllable power factor are suitable for site as well as laboratory testing of three phase kWh meters 
or instruments where specific selection and precise control of outputs are absolutely essential.  

Type

Mains Input

Rated Test Voltage

Creep Test Voltage

Test Current

Starting Current

Input/ phase

Output/
Phase

Metering (Digital)

PLNT1P01

415V, 3 ph., 4 wire, 50Hz. 
AC

230V, 1 ph., 50Hz. 
AC

253V

Continuously variable from 0 
to 
120%. 0-5A,
0-10A & 0-20A

 

0 to 200mA

100VA

50VA

Ammeter-
1 no. Voltmeter-
1no.  
Power Factor meter-
1no.

PLNT3P03

415V, 3 ph., 4 wire, 50Hz. 
AC

110V or 400V, 3 ph., 4 wire, 50Hz. 
AC

121V or 440V

Continuously variable 
0-1A 
or 
0-5A

5, 25mA

30VA

Not less than 5VA

3 nos. Ammeter, 1 no. Voltmeter with selector switch. Phase angle meter-
1no.

PLNT3P04

415V, 3 ph., 4 wire, 50Hz. AC. Optional: 110V

110V or 400V, 3 ph., 4 wire, 50Hz. AC

121V or 440V

Continuously variable
0-1A 
or 
0-5A

5, 25mA

30VA

Not less than 5VA

   

"

PLNT3P05

415V, 3 ph., 4 wire, 50Hz. AC.

110V or 400V, 3 ph., 4 wire, 50Hz. AC

121V or 440V

Continuously variable
0-1A 
or 
0-5A

0.5%, 1%, 1.5% 
of the selected current range

30VA

Not less than 15VA

   

"

Phase Shifter: Capacity 100VA

Type: PLNT1P01 adjustable at any value between 0 lag-0.5 lag-unity-0.5 lead.

Type: PLNT3P03, PLNT3P04, PLNT3P05 adjustable at any value between 0-3600 by coarse and fine control.

Phase sequence indicator with press to read switch.

Apart from the Type of Sets mentioned above, test sets are also manufactured as required by customer.

       -----------Back to Top-----------



           
KWH METER TEST BENCH - 1PH

Single phase kWh meter test bench has been designed to meet the power supply requirement for testing different types of single phase kWh meters and provides high degree of operational convenience to carry 
out calibration checks, performance tests of the meters as per Indian Standard Specification. There is provided terminals for connecting external R.S.S or Wattmeter. It will provide selection and regulation of output voltage and current ranges with full variation of power factor from zero to unity lag, as well as on lead.

A separate meter suspension rack with appropriate wiring and fitting will be supplied. 

Type

Input

Output voltage

Test current

No. of 1 phase kWH meters to be tested

MNTB1P01

3 phase, 4 wire, 400/440V, 50Hz. AC.

Continuously variable 0-260V AC.

0.25, 0.5, 2.5, 10, 20 & 40A

72

MNTB1P02

3 phase, 4 wire, 3x240V/415V, 50Hz AC.

Continuously variable 0–300V AC.

0.25, 0.5, 1, 2.5, 5, 10, 20, 40 , 50 & 100A

40

MNTB1P03

3 phase, 4 wire, 3x240V/415V, 50Hz AC.

Continuously variable 0–300V AC.

0.5, 1, 2.5, 5, 10, 20, 30  & 40A

40

MNTB1P04

3 phase, 4 wire, 400/440V, 50Hz AC.

Continuously variable 230/240VAC.

0.5, 1, 2.5, 5, 10, 20, 40  & 80A

100

MNTB1P05   3 phase, 4 wire, 400V, 50Hz. AC. Subject to variation: -5% to +10% of voltage  &  + 2.5% of frequency   Continuously variable 0 to 230/240V AC.   0.5,1,2.5, 5, 10, 20, 25, 40 & 50A   120  

MNTB1P06

3 phase, 4 wire, 415V, 50Hz AC.

Continuously variable 0-240VAC.

1,  5, 10, 20, 30  & 50A

15

MNTB1P07

3 phase, 4 wire, 400/440V, 50Hz AC.

Continuously variable 0-300V AC.

0.25, 0.5, 1, 2.5, 5, 10 & 20A

50

MNTB1P08

3 phase, 4 wire, 400/440V, 50Hz AC.  
Subject to variation: -5% to +10% of voltage  &  -2% to +1% of frequency

Continuously variable 0-300V AC.

0.25, 0.5, 1, 2.5, 5, 10 , 20 & 40A

50

 
Phase Shifter

Phase Shifting can be done at any value to keep power factor to Unity - 0 lag - Unity - 0  lead.

The test set is also provided with the following facilities.

         Creep test voltage source
         Inching switch
         Starting current of any rated test current. 

Metering:
Voltmeters, Ammeters, Wattmeters' (if any), Flush mounted type.
Power Factor Meter is provided with some of the mentioned test benches.

Protection:
Adequate protection circuit will be provided against overload.
Apart from the existing Types, sets as per requirement of customer may also be manufactured.
 

-----------Back to Top-----------




KWH METER TEST BENCH - 1PH/3PH

Three phase & Single phase kWh meter test bench have been designed to meet the power supply requirement for testing. It will provide selection and regulation of output voltage and current ranges with full variation of power factor from zero to unity lag, as well an on lead. The test bench will facilitate to carry out performance tests of the kWh meters as per IS specification - 722 - 1986 with latest amendment if any. Scope for testing kvarh meters are also provided. CT / PT operated 3 phase kwh / kvarh meters (3 wire/4 wire) can also be tested.

A separate meter suspension rack having capacity to accommodate both single phase and 3 phase meters with appropriate wiring and fitting will be supplied.   


Type: MNTB3P01
3ph. Meter Test Bench


Type: MNTB3P01
Meter Suspension Rack of 3ph. Meter Test Bench

Type

Input

Output voltage

Test current

No. of kWH meters to be tested

MNTB3P01

3 phase, 4 wire, 415V (+10%), 50Hz. AC.

3x110V/64V,
3x220V/127V &
3x440V/254V AC.

0.1,0.25,0.5,1,2.5, 10,20,50 & 100A

3 phase-6nos.
1 phase-15 nos.

MNTB3P02

3 phase, 4 wire, 415V / 3x240V, 50Hz. AC.

3x110V/64V &
3x440V/254V AC.

0.1, 0.25,0.5,1,2.5, 5, 10 & 20A

3 phase-20nos.
1 phase-45 nos.

MNTB3P08

3 phase, 4 wire, 400V, 50Hz. AC.
Subject to variation: 380V to 440V & + 2% of frequency

125-250-500V, 3 phase, 4 wire, 50Hz. AC.

0.1, 0.25, 0.5, 2.5, 5, 10, 20, 30 & 60A

3 phase-20nos.
1 phase- 60 nos. for Creep/MRCD testing
1 phase-30nos. for loading 10-40A.


Type: MNTB3P08
3ph. Meter Test Bench

Type: MNTB3P08
Meter Suspension Rack of 3ph. Meter Test Bench


 Phase Shifter
 Phase Shifting can be done at any value between 0 to 3600 by coarse & fine control.
 The test set is also provided with the following facilities.
 
       Creep test voltage source 
        
Inching switch
        Torque balance
         Burden selection.
         Phase compensation.
         kvarh selector switch.
         Starting current of any rated test current. 

 
Metering: 
  Voltmeters, Ammeters & Wattmeters (if any) Flush mounted type.
  P.F. meter is provided for some specific mentioned Types.

  Protection:
 
Adequate protection circuit will be provided against overload.
  Apart from the existing Types, sets as per requirement of customer may also be 
  manufactured.
                              
                                -----------Back to Top----------
 

                                      Phase Shifting Transformer 

  “NTPL” make portable Phase Shifting Transformer has wide application in the field of electrical engineering, 
   particularly in the field of testing relays having directional element, distance relays, kWh meters, 
   watt meters etc
. The Set is ideal for both laboratory & field use. 




Phase Shifting  Unit of 3 Phase
Phase Shifter in Two Units 
(with phase angle  meter)



Control & Measuring Unit of 3 Phase shifter in Two Units 
(with phase angle meter)

3 Phase Shifter (One Unit) 
(With Phase Angle)

  Input    :            415V, 3 phase, 4 wire, 50Hz. AC. 

  Output  :            3 Ph. Phase Shifter
                          415V, 3ph.,4 wire , 50Hz. AC or 110V, 3 ph., 4 wire, 50Hz. AC.
                                1 Ph. Phase Shifter
                          240V, 1ph. , 50Hz., AC or  63.5V ,1 ph., 50Hz. , AC.

                          Capacity: 250VA / 500VA / 600VA / 750VA / 1 KVA.
                          Phase Shifting can be done at any value between 0 to 3600 by coarse & fine control.

                        
  One direct reading built-in phase angle meter can be provided at an 
                          extra cost.

                                                                
-----------Back to Top----------

 

HOME  |  PROFILE  | PRODUCT  |  CLIENTS  |  CONTACT  |  FEEDBACK

Designed and Maintained  by: Epic
Copyright © 2001,2002 [Neo Tele-Tronix Pvt. Ltd.]. All rights reserved.